Radius Flatwork Forms Commonly Ordered Sets
dee's radius flatwork forming system consists of straight and radius forms used together or separately in conjunction with a wide variety of dee proprietary metal forming accessories.
There are 3 basic industry-standard flatwork configurations for radius concrete placement forming configurations including: sidewalk, driveway and circular pad.
The following tables list the dee components required to form 100 linear feet of radius flatwork setups:
Radius Sidewalk
100’ outside perimeter radius sidewalk; 5” height (assumes a 5” placement depth to calculate a weight)
QTY. | PART # | DESCRIPTION |
---|---|---|
20 | 507 | 5" x 10' radius forms |
20 | 625 | Lock clamps |
11 | 320 | Radius division plates - 5" |
140 | 201 | 3/4" x 18" form pins |
Total Weight for 100 outside perimeter feet = 771 lbs. |
Note: If the applications outside or inside perimeter length or width is not an even multiple of 10, dee radius filler forms (#525) and filler form locks (#688) will also be required.
Radius Driveway
100’ outside perimeter 10' wide radius driveway; 6” height (assumes a 6” placement depth to calculate a weight)
QTY. | PART # | DESCRIPTION |
---|---|---|
20 | 507 | 6" x 10' radius forms |
20 | 625 | Lock clamps |
2 | 205 | 6" x 10' straight forms (for end forms) |
140 | 201 | 3/4" x 18" form pins |
Total Weight for 100 outside perimeter feet = 1,044 lbs. |
Note: If the concrete placement depth exceeds 12", twice the number of lock clamps (#625) are required.
Note: If the applications outside or inside perimeter length or width is not an even multiple of 10, dee radius filler forms (#525) and filler form locks (#688) will also be required.
Note: If the application's width is greater than 10 feet and is not an even multiple of 10, dee straight filler forms (#255) wil also be required.
Radius Circular Pad
100' circumference circular pad; (assumes an 8” placement depth to calculate a weight)
QTY. | PART # | DESCRIPTION |
---|---|---|
10 | 507 | 8" x 10' radius forms |
10 | 625 | Lock clamps |
70 | 201 | 3/4" x 18" form pins |
Total Weight for 100 outside perimeter feet = 645 lbs. |
Note: If the concrete placement depth exceeds 12", twice the number of lock clamps (#625) are required.
Note: If the applications outside or inside perimeter length or width is not an even multiple of 10, dee radius filler forms (#525) and filler form locks (#688) will also be required.
Flatwork forms must be verified before placing orders to ensure proper components are ordered. View dee's ordering guidelines now.